To install, copy the source code of the script, then add to Shelly device using one of Shelly provided options.
For your convenience, you can add following url to scripts source in your Shelly:
https://raw.githubusercontent.com/michalk-k/shelly-scripts/main/manifest.json
Read documentation for further steps.
It requires the MQTT to be enabled and configured in the Shelly device.
The script registers the Shelly device the script runs on and its entities, to Home Assistant, using MQTT discovery.
It creates entities for all supported properties: switches, sensors etc.
Currently supports following SHelly components (they can be found in different SHelly devices):
- switch
- cover (incl. position and slat if enabled)
- pm1
- wifi *)
- em, em1
- emdata, em1data
- temperature **)
Important: Some Shelly configuration changes, requires re-execution of the script. It might be change from switch to light, enabling position control by making a cover calibration or enabling slat control in Shelly settings.
Compatibility with devices depends on components those devices implement. Tested with following devices (click on them for screenshots):
Plus 2PM (gen2) - as switch, light, cover incl. position and slat support
Cover device page:
Double switch device page (one switch in light mode):

Cover options:




Pro EM3 (gen2) - both triphase and monophase profiles
**Triphase**  **Monophase** *) wifi component isn't originally repoted to MQTT. This script adds periodical reporting of Wifi component status to topic configured in MQTT configuration
**) Shelly devices report temperature only on temperature changes. Once temperature stabilizes, MQTT topic is not updated anymore. In conjunction with non-retained topic, it might lead to unknown value for long time, ie after HA restart or HA entity reinitialization.✅ - confirmed by comparison of components implemented in the script
☑️ - as above, but support is limited to subset of available device profiles.
✔️ - tested by me
Gen 2 devices
| Device Name | Components | Supported |
|---|---|---|
| Shelly Plus 1 (Mini) | switch | ✅ |
| Shelly Plus 1 PM (Mini) | switch, | ✅ ✔️ |
| Shelly Plus 2 PM | switch, cover | ✅ ✔️ |
| Shelly Plus I4 | input | ✅ |
| Shelly Plus Plug IT | switch, | ✅ |
| Shelly Plus Plug S | switch, | ✅ |
| Shelly Plus Plug UK | switch, | ✅ |
| Shelly Plus Plug US | switch, | ✅ |
| Shelly Plus H & T | humidity, temperature, devicepower | |
| Shelly Plus Smoke | smoke | |
| Shelly Plus WallDimmer | light | |
| Shelly Plus RGBW PM | light, rgb, rgbw | |
| Shelly Plus 0 – 10 V Dimmer | light | |
| Shelly Plus PM Mini | switch, pm1 | ✅ |
| Shelly Plus Uni | switch, temperature, humidity, voltmeter | ☑️ (switch only) |
| Shelly Pro 1 | switch | ✅ |
| Shelly Pro 1 PM | switch | ✅ |
| Shelly Pro 2 | switch | ✅ |
| Shelly Pro 2 PM | switch, cover | ✅ |
| Shelly Pro 3 | switch | ✅ |
| Shelly Pro 4 PM | switch | ✅ |
| Shelly Pro Dual Cover PM | cover | ✅ |
| Shelly Pro EM | switch, em1, em1data | ✅ |
| Shelly Pro 3 EM (400) | em, em1, emdata, em1data | ✅ ✔️ |
| Shelly Pro Dimmer 1 PM | light | |
| Shelly Pro Dimmer 2 PM | light | |
| Shelly Pro Dimmer 0/1 – 10 V PM | light | |
| Shelly Pro RGBWW PM | light, rgb, cct | |
| Shelly BLU Gateway | (none) |
Gen 3 devices
| Device Name | Components | Supported |
|---|---|---|
| Shelly 1 | switch | ✅ |
| Shelly 1 PM | switch | ✅ |
| Shelly 2 PM | switch, cover | ✅ |
| Shelly I4 / I4DC | input | |
| Shelly 1 L | switch | ✅ |
| Shelly 2 L | switch | ✅ |
| Shelly 1 Mini | switch | ✅ |
| Shelly 1 PM Mini | switch | ✅ |
| Shelly PM Mini | pm1 | ✅ ✔️ |
| Shelly AZ Plug | switch | ✅ |
| Shelly Plug S | switch | ✅ |
| Shelly Outdoor Plug S | switch | ✅ |
| Shelly Dimmer 0/1 – 10 V PM | light | |
| Shelly Dimmer | light | |
| Shelly D Dimmer | light | |
| Shelly H & T | humidity, temperature, devicepower | |
| Shelly 3 EM | em, em1data | ✅ |
| Shelly EM | em1, em1data | ✅ |
| Shelly BLU Gateway Gen3 | (none) | |
| Shelly Shutter | cover |
Gen 4 devices
| Device Name | Components | Supported |
|---|---|---|
| Shelly 1 | switch | ✅ |
| Shelly 1 PM | switch | ✅ |
| Shelly 1 Mini | switch | ✅ |
| Shelly 1 PM Mini | switch | ✅ |
| Shelly 2 PM | switch | ✅ |
- easy to use: just run it
- by default creates generic device and entity names (see Naming below)
- device and entity names might be taked from shelly configuration
- switch can be reported as a light entity to HA (set
consumption typetolight) - some of sensors are disabled by default, for example power factor or voltage.
- The script follows recent Home Assistant conventions in how to setup entities.
- force MQTT refresh to selected components, incl. WiFi
Device
The device name follows the pattern: : macaddress-modelname, for example b8d6xxxxxxxx-Plus2PM.
It can be overriden by setting Device name (Settings / Device Name). To apply changes, the script must be restarted
Note, the Home Assistant uses device name as a prefix for entity names. Changing device when entities are already registered, affect no entity names
Entities
By default entity name follows the tracked attribute function, for example: Switch, Frequency, Power Factor, RSSI. If the device contains more components of the same type (ie measurement channels), the names are suffixed by oridinal numbers, for example Switch 1, Switch 2, Frequency 1, Frequency 2, etc.
If device channel has a custom name configured (as for example, Output -> Name in Shelly2PM), all related entity names gets name as follows: Custom Name Function, For example Dryer Socket Frequency. in this case the oridinal number of Shelly component is not appended.
The friendly_name is created by Home Assistant from the device name and the entity name. It might look like b8d6xxxxxxxx-Plus2PM Active Power 2 or b8d6xxxxxxxx-Plus2PM Backlight. Looks horrible, but once device name is changed to something meaningfull, ie AlcoveLight, the friendly name will turn into AlcoveLight Active Power 2 or AlcoveLight Backlight respectively.
The unique_id allways follows the pattern: macaddress-function or macaddress-function-number, for example macaddress-rssi or b8d6xxxxxxxx_power_factor_1. Unique id never changes and is not influenced by configuration settings.
The entity_id is not set by this script. The entity name is generated by Home Assistant from device_name_entity_name pattern, for example sensor.b8d61a89xxxx_plus2pm_active_energy_2. The entity_id may be influenced by the Device name set in Shelly configuration or changed later on in Home Assistant.
It's often useful to have a switch interpreted by Home Assistant as a light.
It can be achieved in Home Assistant with use of "Change device type of a switch" helper. But it creates additional entity in the system.
Shelly devices allows to enter this information into (Output Settings -> Consumption Type). Entering light makes the switch be reported as a light to Home Assistant.
Currently only
lightas alternative device class is supported
Note, that the change neither influences unique_id, entity_id or mqtt topic names. But it will change the entity name and friendly name of the entity.