I have checked how rLakeAnalyzer performed the internal energy calculation and there seems to be an error in the units.
Internal energy = sum(volumedensitytemperature*Cpw)/Surface area
Cpw is 4186 J kg-1 degK-1, then temperature should be in kelvin as well (in the function internal.energy.R wtr is in degC)