Notifications
You must be signed in to change notification settings - Fork 1
Open
Labels
bugSomething isn't workingSomething isn't working
Description
Investigate/fix temperature issue with model 5v1
Temp values for thermistor temp do change with a change in temperature, but the offset/scale is off significantly. Looks like a resistor value problem or a Beta value problem
Issue Details:
The Temp DH value returns the correct value but Temp DHt does not. Appears to be limited to model 5v1 but verify this is the case!
Potential Solutions:
Looks to be a scaling/offset issue, verify correct beta value and thermistor/resistor values. Likely just a coefficient issue for the 5v1 model
Example Values:
| Temp DH [C] | Temp DHt [C] |
|---|---|
| 27.61 | 75.31 |
| 23.32 | 63.97 |
| 13.64 | 55.84 |
| 7.32 | 47.18 |
| 3.25 | 43.36 |
Note: Temp DH is correct value, Temp DHt is unknown incorrect value
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
bugSomething isn't workingSomething isn't working