Notifications
You must be signed in to change notification settings - Fork 52
Open
Description
Not sure if it's an ESPHome bug, but I get this only with esphome-opentherm. After I restart Home Assistant, the integration fails with this error:
Error setting up entry opentherm for esphome
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/config_entries.py", line 382, in async_setup
result = await component.async_setup_entry(hass, self)
File "/usr/src/homeassistant/homeassistant/components/esphome/__init__.py", line 370, in async_setup_entry
infos, services = await entry_data.async_load_from_store()
File "/usr/src/homeassistant/homeassistant/components/esphome/entry_data.py", line 228, in async_load_from_store
infos.append(cls.from_dict(info))
File "/usr/local/lib/python3.10/site-packages/aioesphomeapi/model.py", line 87, in from_dict
return cls(**init_args)
File "<string>", line 16, in __init__
File "/usr/local/lib/python3.10/site-packages/aioesphomeapi/model.py", line 73, in __post_init__
super().__setattr__(field_.name, convert(val))
File "/usr/local/lib/python3.10/site-packages/aioesphomeapi/util.py", line 49, in fix_float_single_double_conversion
if value == 0 or not math.isfinite(value):
TypeError: must be real number, not NoneType
This is the yaml configuration:
substitutions:
devicename: opentherm
upper_devicename: Opentherm
esphome:
name: $devicename
platform: ESP8266
board: d1_mini
esp8266_restore_from_flash: true
external_components:
source: github://arthurrump/esphome-opentherm@main
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
ap:
ssid: "${devicename} Fallback"
password: !secret wifi_password
web_server:
port: 80
captive_portal:
logger:
api:
encryption:
key: <redacted>
ota:
password: <redacted>
opentherm:
in_pin: 12
out_pin: 14
ch_enable: true
dhw_enable: true
output:
- platform: opentherm
t_set:
id: t_set
min_value: 15
auto_max_value: true
zero_means_zero: true
number:
- platform: opentherm
t_dhw_set:
name: "Boiler DHW Setpoint"
auto_min_value: true
auto_max_value: true
max_t_set:
name: "Maximum allowable CH water setpoint"
sensor:
- platform: opentherm
rel_mod_level:
name: "Boiler Relative modulation level"
t_boiler:
name: "Boiler water temperature"
ch_pressure:
name: "Boiler Water pressure in CH circuit"
t_dhw:
name: "DHW temperature"
t_dhw_set:
name: "Domestic hot water temperature setpoint"
- platform: homeassistant
id: ch_room_temperature
entity_id: sensor.ble_temperature_a4c1384e0601
filters:
# Push room temperature every second to update PID parameters
- heartbeat: 1s
binary_sensor:
- platform: opentherm
ch_active:
name: "Boiler Central Heating active"
dhw_active:
name: "Boiler Domestic Hot Water active"
flame_on:
name: "Boiler Flame on"
fault_indication:
name: "Boiler Fault indication"
entity_category: diagnostic
diagnostic_indication:
name: "Boiler Diagnostic event"
entity_category: diagnostic
dhw_present:
name: "Configuration: DHW present"
entity_category: diagnostic
ch2_present:
name: "Configuration: CH2 present"
switch:
- platform: opentherm
ch_enable:
name: "Boiler Central Heating enabled"
mode: restore_default_on
climate:
- platform: pid
name: "Central heating"
heat_output: t_set
default_target_temperature: 20
sensor: ch_room_temperature
control_parameters:
kp: 0.4
ki: 0.004
deadband_parameters:
threshold_high: 0.3°C # deadband within +/-0.5°C of target_temperature
threshold_low: -0.3°C
visual:
temperature_step: 0.5 °C
This happens with ESPHome 2023.2.4. Any idea what could trigger that error?