This plugin gathers metrics on system temperatures.
⭐ Telegraf v1.8.0 🏷️ hardware, system 💻 linux, macos, windows
Plugins support additional global and plugin configuration settings for tasks such as modifying metrics, tags, and fields, creating aliases, and configuring plugin ordering. See CONFIGURATION.md for more details.
# Read metrics about temperature
[[inputs.temp]]
## Desired output format (Linux only)
## Available values are
## v1 -- use pre-v1.22.4 sensor naming, e.g. coretemp_core0_input
## v2 -- use v1.22.4+ sensor naming, e.g. coretemp_core_0_input
# metric_format = "v2"
## Add device tag to distinguish devices with the same name (Linux only)
# add_device_tag = falseOn Windows, the plugin uses a WMI call that is can be replicated with the following command:
wmic /namespace:\\root\wmi PATH MSAcpi_ThermalZoneTemperatureIf the result is "Not Supported" you may be running in a virtualized environment and not a physical machine. Additionally, if you still get this result your motherboard or system may not support querying these values. Finally, you may be required to run as admin to get the values.
- temp
- tags:
- sensor
- fields:
- temp (float, celcius)
- tags:
temp,sensor=coretemp_physicalid0_crit temp=100 1531298763000000000
temp,sensor=coretemp_physicalid0_critalarm temp=0 1531298763000000000
temp,sensor=coretemp_physicalid0_input temp=100 1531298763000000000
temp,sensor=coretemp_physicalid0_max temp=100 1531298763000000000