Hi, I built the OCP module and it all works ok. It was calibrated using a 51/2 digit Keithley 2000 multimeter and all went OK. But, when I measure the voltages on the outputs (using all the Apps and Voltages App), they all seem to be around 10mv out/high, as if there is an offset being applied. Obviously, 10mv error is quite a lot when the module is capable of being calibrated to 0.1mv.
I’ve contacted Shay from Plum and he has checked this and found the same thing, putting it down to a bug in the firmware (1.3.6). He has asked me to also submit it here so that it can be fixed in the next release. Thanks. SJ.
Hi, I built the OCP module and it all works ok. It was calibrated using a 51/2 digit Keithley 2000 multimeter and all went OK. But, when I measure the voltages on the outputs (using all the Apps and Voltages App), they all seem to be around 10mv out/high, as if there is an offset being applied. Obviously, 10mv error is quite a lot when the module is capable of being calibrated to 0.1mv.
I’ve contacted Shay from Plum and he has checked this and found the same thing, putting it down to a bug in the firmware (1.3.6). He has asked me to also submit it here so that it can be fixed in the next release. Thanks. SJ.