Skip to content

The Default HVAC Library object "MultiSpeed Heat Pump AirToAir" is not a Heat Pump #834

@Ski90Moo

Description

@Ski90Moo

Enhancement Request

The object in the default HVAC library named "MultiSpeed Heat Pump AirToAir" is mislabeled. It is categorized in the "AirLoopHVAC Unitary Heat Pump AirToAir MultiSpeed" category, but the object does not contain a DX heating coil used for a heat pump. The primary heating coil is a 2-stage gas heating coil and the supplementary heating coil is electric.

Detailed Description

Image

Possible Implementation

Metadata

Metadata

Assignees

No one assigned

    Labels

    Enhancement RequestNew feature or requestTriageIssue needs to be assessed and labeled, further information on reported might be needed

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions