@@ -16,10 +16,10 @@ The AC Power Switch is the most-used Switch variant. It provides a standard NEMA
1616

1717
The heart of the switch is an Xiamen Hongfa Electroacoustic HF165FD-G high-power relay. The relay is UL rated for:
1818

19-
* 40A 277VAC 40C
20-
* 1HP 120VAC 40C
21-
* 96LRA/30FLA 40C
22-
* TV-8 125VAC 40C
19+
* 40A 277VAC 40C
20+
* 1HP 120VAC 40C
21+
* 96LRA/30FLA 40C
22+
* TV-8 125VAC 40C
2323

2424
The relay is wired in a normally-open configuration, so that a lack of control signal or an internal power fault results in a shutdown within 10 milliseconds. Only the live is interrupted, neutral and earth are always connected for safety purposes.