Skip to content

Commit 4a586e7

Browse files
committed
docs: update boards/Dropbear
1 parent 110e79a commit 4a586e7

File tree

1 file changed

+27
-27
lines changed

1 file changed

+27
-27
lines changed

boards/Dropbear.md

Lines changed: 27 additions & 27 deletions
Original file line numberDiff line numberDiff line change
@@ -2,7 +2,7 @@
22
title: Dropbear
33
description:
44
published: true
5-
date: 2024-12-08T02:56:50.482Z
5+
date: 2024-12-08T23:59:49.219Z
66
tags:
77
editor: markdown
88
dateCreated: 2020-12-24T00:42:27.964Z
@@ -69,32 +69,32 @@ The Dropbear ECU uses 2x 24 pin Delphi Sicma connectors. The connectors are keye
6969
> Note connector alignment in above image
7070
{.is-info}
7171

72-
| Pin | Direction | Max Current | Purpose | Comment |
73-
|-----|-----------|--------------|-----------------|-------------------------------------------------------------------------|
74-
| A1 | Output | 2A | Injector 1 | Injector 1 output |
75-
| A2 | Output | 2A | Injector 2 | Injector 2 output |
76-
| A3 | Output | 2A | Injector 3 | Injector 3 output |
77-
| A4 | Output | 2A | Injector 4 | Injector 4 output |
78-
| A5 | Output | 2A | Injector 5 | Injector 5 output |
79-
| A6 | Output | 2A | Injector 6 | Injector 6 output |
80-
| A7 | Output | 2A | Injector 7 | Injector 7 output |
81-
| A8 | Output | 2A | Injector 8 | Injector 8 output |
82-
| B1 | Output | 100mA | Ignition 1 | Ignition 1 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
83-
| B2 | Output | 100mA | Ignition 2 | Ignition 2 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
84-
| B3 | Output | 100mA | Ignition 3 | Ignition 3 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
85-
| B4 | Output | 100mA | Ignition 4 | Ignition 4 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
86-
| B5 | Output | 100mA | Ignition 5 | Ignition 5 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
87-
| B6 | Output | 100mA | Ignition 6 | Ignition 6 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
88-
| B7 | Output | 100mA | Ignition 7 | Ignition 7 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
89-
| B8 | Output | 100mA | Ignition 8 | Ignition 8 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
90-
| C1 | Output | 2A | Boost | Ground switching output for use with boost control solenoid |
91-
| C2 | Output | 2A | Fan. | Ground switching output for triggering a fan relay. **Do not drive fan directly from this pin, use only with relay** |
92-
| C3 | Output | 2A | Spare 2/Stepper-B2 | Can be used either as ground switching output for general purpose use or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). Tuner Studio pin #26 |
93-
| C4 | Output | 2A | Idle/Stepper-B1 | Can be used either as ground switching idle output (For use with PWM valves) or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). <br/>Tuner Studio pin #27 |
94-
| C5 | Output | 2A | VVT/Stepper-A1. | Can be used either as ground switching VVT output or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). <br/>Tuner Studio pin #28 |
95-
| C6 | Output | 2A | Spare 1/Idle 2/Stepper-A2 | Can be used either as ground switching output for general purpose use or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). This is the default pin for Idle 2 when using a 3 wire PWM valve. <br/>Tuner Studio pin #29 |
96-
| C7 | Output | 1.5A | Fuel Pump | Ground switching output for triggering fuel pump relay. **Do not drive pump directly from this pin, use only with relay** |
97-
| C8 | Input | 15A | Power Ground | Connect to battery negative. |
72+
| Pin | Direction | Max Current | Purpose | Tuner Studio Pin | Comment |
73+
|-----|-----------|--------------|-----------------|-----|-------------------------------------------------------------------------|
74+
| A1 | Output | 2A | Injector 1 | N/A | Injector 1 output |
75+
| A2 | Output | 2A | Injector 2 | N/A | Injector 2 output |
76+
| A3 | Output | 2A | Injector 3 | N/A | Injector 3 output |
77+
| A4 | Output | 2A | Injector 4 | N/A | Injector 4 output |
78+
| A5 | Output | 2A | Injector 5 | N/A | Injector 5 output |
79+
| A6 | Output | 2A | Injector 6 | N/A | Injector 6 output |
80+
| A7 | Output | 2A | Injector 7 | N/A | Injector 7 output |
81+
| A8 | Output | 2A | Injector 8 | N/A | Injector 8 output |
82+
| B1 | Output | 100mA | Ignition 1 | N/A | Ignition 1 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
83+
| B2 | Output | 100mA | Ignition 2 | N/A | Ignition 2 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
84+
| B3 | Output | 100mA | Ignition 3 | N/A | Ignition 3 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
85+
| B4 | Output | 100mA | Ignition 4 | N/A | Ignition 4 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
86+
| B5 | Output | 100mA | Ignition 5 | N/A | Ignition 5 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
87+
| B6 | Output | 100mA | Ignition 6 | N/A | Ignition 6 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
88+
| B7 | Output | 100mA | Ignition 7 | N/A | Ignition 7 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
89+
| B8 | Output | 100mA | Ignition 8 | N/A | Ignition 8 output. 5v or 12v depending on switch selection. **Do not connect directly to high current coils**, only connect to igniter or 'smart' coil |
90+
| C1 | Output | 2A | Boost | 24 | Ground switching output for use with boost control solenoid |
91+
| C2 | Output | 2A | Fan. | 25 | Ground switching output for triggering a fan relay. **Do not drive fan directly from this pin, use only with relay** |
92+
| C3 | Output | 2A | Spare 2/Stepper-B2 | 26 | Can be used either as ground switching output for general purpose use or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)).
93+
| C4 | Output | 2A | Idle/Stepper-B1 | 27 | Can be used either as ground switching idle output (For use with PWM valves) or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). |
94+
| C5 | Output | 2A | VVT/Stepper-A1. | 28 | Can be used either as ground switching VVT output or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). |
95+
| C6 | Output | 2A | Spare 1/Idle 2/Stepper-A2 | 29 | Can be used either as ground switching output for general purpose use or 12v output if using a stepper idle control (Requires stepper driver to be fitted, see [Stepper Driver](#stepper-driver)). This is the default pin for Idle 2 when using a 3 wire PWM valve. |
96+
| C7 | Output | 1.5A | Fuel Pump | N/A | Ground switching output for triggering fuel pump relay. **Do not drive pump directly from this pin, use only with relay** |
97+
| C8 | Input | 15A | Power Ground | N/A | Connect to battery negative. |
9898

9999
## Board Configuration
100100
The Dropbear board contains 4 switches and 1 DIP switch pair that can be used to change the setup of the ECU.

0 commit comments

Comments
 (0)