snd_tlv_convert_to_dB: Fix mute handling for MINMAX_MUTE type #478
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Ensure the SND_CTL_TLV_DB_GAIN_MUTE value is returned when the calculated gain equals the minimum dB value for the SNDRV_CTL_TLVT_DB_MINMAX_MUTE type. The previous check based solely on the volume value could miss cases where the linear calculation resulted in the minimum gain.
The db range of some devices is very small