23 changes: 14 additions & 9 deletions docs/section6/Rule6-5.md
Original file line number Diff line number Diff line change
Expand Up @@ -6,9 +6,8 @@
**Appendix G Section:** Section G3.1-6 Modeling Requirements for the Baseline building
**Appendix G Section Reference:** None

**Applicability:** All required data elements exist for B_RMR
**Applicability Checks:**

**Applicability:** All required data elements exist for B_RMD
**Applicability Checks:**
1. Building total area is more than 5,000sq.ft.

**Manual Check:** Yes
Expand All @@ -30,24 +29,30 @@
- **Applicability Check 1:**`if building_total_area_b > 5000:`

- For each space in building_b: `space_b in building_b...spaces:`
- Get total lighting power density in space: `total_space_LPD_b = sum(interior_lighting.power_per_area for interior_lighting in space_b.interior_lighting)`

- Skip evaluating plenums, crawlspaces, and interstitial spaces that have no lighting power: `if total_space_LPD_b ==0 and space_b.function in [PLENUM, CRAWL_SPACE, INTERSTITIAL_SPACE]: continue`

- Get normalized space lighting schedule: `normalized_schedule_b = normalize_interior_lighting_schedules(space_b.interior_lighting, false)`

- Get matching space in P_RMR: `space_p = match_data_element(P_RMR, Spaces, space_b.id)`
- Get matching space in P_RMD: `space_p = match_data_element(P_RMD, Spaces, space_b.id)`

- Get normalized space lighting schedule in P_RMR: `normalized_schedule_p = normalize_interior_lighting_schedules(space_p.interior_lighting, false)`
- Get normalized space lighting schedule in P_RMD: `normalized_schedule_p = normalize_interior_lighting_schedules(space_p.interior_lighting, false)`

- Check if automatic shutoff control is modeled in space during building closed hours (i.e. if lighting schedule hourly value in B_RMR is equal to P_RMR during building closed hours): `schedule_comparison_result = compare_schedules(normalized_schedule_b, normalized_schedule_p, inverse(building_open_schedule_b))`
- Check if automatic shutoff control is modeled in space during building closed hours (i.e. if lighting schedule hourly value in B_RMD is equal to P_RMD during building closed hours): `schedule_comparison_result = compare_schedules(normalized_schedule_b, normalized_schedule_p, inverse(building_open_schedule_b))`

**Rule Assertion:**

- Case 1: For building closed hours, if lighting schedule hourly value in B_RMR is equal to P_RMR: `if schedule_comparison_result["total_hours_compared"] == schedule_comparison_result["total_hours_matched"]: PASS`
- Case 1: If space has lighting power and is crawl space, interstitial space, or plenum: UNDETERMINED `if ( total_space_LPD_b > 0 ) AND ( space_function_b in [CRAWL_SPACE, INTERSTITIAL_SPACE, PLENUM] ): UNDETERMINED and raise_warning f"Space function is {space_function_b} and has lighting power modeled. Unable to determine whether this space should be included in the check."`

- Case 2: For building closed hours, if lighting schedule hourly value in B_RMD is equal to P_RMD: `if schedule_comparison_result["total_hours_compared"] == schedule_comparison_result["total_hours_matched"]: PASS`

- Case 2: Else: `else: Failed`
- Case 3: Else: `else: Failed`


**Notes:**
1. Updated the Rule ID from 6-9 to 6-6 on 6/3/2022
2. Updated the Rule ID from 6-6 to 6-5 on 6/8/2022
2. Updated the Rule ID from 6-6 to 6-5 on 6/8/2022
3. Updated to exclude crawl space, plenum or interstitial space on 9/29/2025.

**[Back](../_toc.md)**