.SYNOPSIS
Enables Special Administration Console (SAC) and Serial Console boot settings.

.DESCRIPTION
Configures BCD to enable the boot menu, set a timeout, and turn on EMS/SAC
to allow serial console access to the VM.
Created by Tony.Mocanu@Microsoft.com
This script runs from a rescue VM to enable SAC/EMS on an attached OS disk's BCD store.
It performs the following steps:
1. Enumerates attached partitions via Get-Disk-Partitions to locate the BCD store and OS loader.
1a. For Gen2 disks where the EFI partition has no drive letter, uses diskpart to
temporarily assign one so the BCD store can be accessed.
2. Identifies the default boot entry GUID from the BCD bootmgr displayorder.
3. Logs the BCD configuration before any changes are made.
4. Enables the boot menu with a 5-second timeout (displaybootmenu, timeout).
5. Enables Boot EMS on the boot manager (bootems yes).
6. Enables EMS on the default OS entry (ems ON).
7. Configures EMS settings for serial console (EMSPORT:1, EMSBAUDRATE:115200).
8. Logs the BCD configuration after changes for verification.

.NOTES
Name: sac-enabler.ps1
Author: Tony.Mocanu@Microsoft.com

.VERSION
v1.3: [May 2026] - Updated the script again (current)
- Fixed breaking exception when the Hyper-V module is not installed on the host.
- Added explicit checking via Get-Module before executing nested VM discovery.
v1.2: [May 2026] - Updated the script
- Included advanced Gen2 unlettered EFI fallback and dynamic drive-letter assignment.
v0.1: Initial commit. This was the version 1.0 of the script.

.SCENARIO_RECREATION
To recreate a testable scenario on a rescue VM with an attached OS disk:
1. Create a test VM in Azure and attach its OS disk to a rescue VM.
2. The BCD store is on the System Reserved (Gen1) or EFI (Gen2) partition, which
may not have a drive letter. Find it by scanning all volumes (run as Admin):
Get-Volume | Where-Object { $_.DriveLetter } | ForEach-Object { $d = $_.DriveLetter; @("$d`:\boot\bcd","$d`:\efi\microsoft\boot\bcd") | Where-Object { Test-Path $_ } | ForEach-Object { Write-Output "FOUND: $_" } }
If nothing is found, the partition has no drive letter. For System Reserved (Gen1):
Get-Partition | Where-Object { -not $_.DriveLetter -and $_.Size -lt 1GB } | Format-Table DiskNumber, PartitionNumber, Size, Type
Set-Partition -DiskNumber <disk> -PartitionNumber <part> -NewDriveLetter S
For EFI partitions (Gen2), Set-Partition won't work -- use diskpart instead:
diskpart
select disk <disk>
select partition <part>
assign letter=S
exit
Then check: Test-Path S:\boot\bcd or Test-Path S:\efi\microsoft\boot\bcd

Example with two attached disks (from Disk Management):
Disk 2 (Gen1): System Reserved (F:) 500 MB | Windows (G:) 126 GB
-> BCD already accessible at F:\boot\bcd
Disk 3 (Gen2): 450 MB (no letter) | EFI (no letter) 99 MB | Windows (H:) 126 GB
-> EFI partitions are protected; use diskpart to assign a letter:
diskpart
select disk 3
select partition 2
assign letter=S
exit
-> BCD at S:\efi\microsoft\boot\bcd

3. Once you have the BCD path, disable SAC/EMS to simulate a broken VM:

Gen1 example (F:\boot\bcd):
bcdedit /store F:\boot\bcd /ems "{default}" OFF
bcdedit /store F:\boot\bcd /set "{bootmgr}" bootems no
bcdedit /store F:\boot\bcd /set "{bootmgr}" displaybootmenu no

Gen2 example (S:\efi\microsoft\boot\bcd):
bcdedit /store S:\efi\microsoft\boot\bcd /ems "{default}" OFF
bcdedit /store S:\efi\microsoft\boot\bcd /set "{bootmgr}" bootems no
bcdedit /store S:\efi\microsoft\boot\bcd /set "{bootmgr}" displaybootmenu no

4. Verify EMS is disabled:
bcdedit /store F:\boot\bcd /enum "{default}"
bcdedit /store F:\boot\bcd /enum "{bootmgr}"
Expected: ems = No or absent, bootems = No or absent.
5. Run the script. It should enable ems, bootems, displaybootmenu, and emssettings.
6. Verify all SAC settings are now enabled (see .VERIFICATION section).

.EXAMPLE
az vm repair run -g <rg> -n <vm> --run-id win-sac-enabler --run-on-repair

.VERIFICATION
1. Check the log file for success:
Get-ChildItem "C:\WindowsAzure\Logs\Plugins\Microsoft.Compute.CustomScriptExtension\sac-enabler_*.log" | Sort-Object LastWriteTime -Descending | Select-Object -First 1 | Get-Content
Expected: "BCD AFTER SAC ENABLE" section present and return code 0 ($STATUS_SUCCESS).
2. Manually verify the BCD store (replace drive letters with the ones found in step 2):

Gen1 (System Reserved on F:):
bcdedit /store F:\boot\bcd /enum "{default}"
bcdedit /store F:\boot\bcd /enum "{bootmgr}"

Gen2 (EFI partition -- use diskpart to assign a letter if needed, e.g. P:):
bcdedit /store P:\efi\microsoft\boot\bcd /enum "{default}"
bcdedit /store P:\efi\microsoft\boot\bcd /enum "{bootmgr}"

Expected: ems = Yes on the OS entry, bootems = Yes on bootmgr,
displaybootmenu = Yes, timeout = 5, EMSPORT = 1, EMSBAUDRATE = 115200.

NOTE: For Gen2 disks, the script automatically assigns a temporary drive letter
to the EFI System Partition via diskpart if Get-Disk-Partitions did not assign one.
The temporary letter is removed after processing.
#>

# 1. Initialize script and helper functions
# Initialization
. .\src\windows\common\setup\init.ps1
. .\src\windows\common\helpers\Get-Disk-Partitions.ps1
. .\src\windows\common\helpers\Get-Disk-Partitions-v2.ps1

# 2. Set Log Path to Public Desktop
$logFile = "C:\Users\Public\Desktop\sac-enabler-log.txt"
# Log Configuration
$logDir = "C:\WindowsAzure\Logs\Plugins\Microsoft.Compute.CustomScriptExtension"
if (-not (Test-Path $logDir)) { $null = New-Item -ItemType Directory -Path $logDir -Force }
$timestamp = Get-Date -Format "yyyyMMdd_HHmmss"
$logFile = "$logDir\sac-enabler_$timestamp.log"

# 3. Execution Logic
$partitionlist = Get-Disk-Partitions
Log-Info '#03 - Enumerate partitions to enable SAC' | Tee-Object -FilePath $logFile -Append
# Status Tracking
$script_final_status = $STATUS_ERROR

foreach ( $partitionGroup in $partitionlist | group DiskNumber )
{
$isBcdPath = $false
$bcdPath = ''
$isOsPath = $false
try {
# Check if the Hyper-V module is available before performing nested VM checks
if (Get-Module -ListAvailable -Name Hyper-V) {
$guestHyperVVirtualMachine = Get-VM -ErrorAction SilentlyContinue -WarningAction SilentlyContinue
if ($guestHyperVVirtualMachine) {
if ($guestHyperVVirtualMachine.State -eq 'Running') {
Log-Info "Stopping nested guest VM $($guestHyperVVirtualMachine.VMName)" | Tee-Object -FilePath $logFile -Append
try {
Stop-VM $guestHyperVVirtualMachine -ErrorAction Stop -Force
}
catch {
Log-Warning "Failed to stop nested guest VM, will continue but may have limited success" | Tee-Object -FilePath $logFile -Append
}
}
}
} else {
Log-Info "Hyper-V PowerShell module is not available on this host. Skipping nested VM validation." | Tee-Object -FilePath $logFile -Append
}

# Step 1 - Enumerate partitions to locate the BCD store and OS loader
$partitionlist = Get-Disk-Partitions
$rescueDrive = $env:SystemDrive -replace ':', ''
Log-Info 'Enumerating partitions to enable SAC...' | Tee-Object -FilePath $logFile -Append

foreach ( $partitionGroup in $partitionlist | group DiskNumber )
{
$isBcdPath = $false
$bcdPath = ''
$isOsPath = $false

# Discovery Logic (Matches your BCD logic for consistency)
ForEach ($drive in $partitionGroup.Group | select -ExpandProperty DriveLetter )
{
if ( -not $isBcdPath )
# Scan each drive for BCD store and Windows OS loader
ForEach ($drive in $partitionGroup.Group | select -ExpandProperty DriveLetter )
{
$bcdPath = $drive + ':\boot\bcd'
$isBcdPath = Test-Path $bcdPath
# Skip the rescue VM's own OS drive
if ($drive -eq $rescueDrive) { continue }

if ( -not $isBcdPath )
{
$bcdPath = $drive + ':\efi\microsoft\boot\bcd'
$bcdPath = $drive + ':\boot\bcd'
$isBcdPath = Test-Path $bcdPath
}
}
if (-not $isOsPath)
if ( -not $isBcdPath )
{
$bcdPath = $drive + ':\efi\microsoft\boot\bcd'
$isBcdPath = Test-Path $bcdPath
}
}
if (-not $isOsPath)
{
$isOsPath = Test-Path ($drive + ':\windows\system32\winload.exe')
}
}

# Gen2 EFI fallback: if OS found but no BCD, discover unlettered EFI partition
$tempEfiLetter = $null
$tempEfiDiskNum = $null
$tempEfiPartNum = $null
if (-not $isBcdPath -and $isOsPath)
{
$isOsPath = Test-Path ($drive + ':\windows\system32\winload.exe')
$diskNum = [int]$partitionGroup.Name
$rescueDiskNum = (Get-Partition -DriveLetter $rescueDrive -ErrorAction SilentlyContinue | Select-Object -First 1).DiskNumber
if ($diskNum -ne $rescueDiskNum)
{
Log-Info "Disk ${diskNum}: OS found but no BCD - checking for unlettered EFI partition (Gen2)..." | Tee-Object -FilePath $logFile -Append
$efiGptType = '{c12a7328-f81f-11d2-ba4b-00a0c93ec93b}'
$efiParts = Get-Partition -DiskNumber $diskNum -ErrorAction SilentlyContinue | Where-Object {
$_.GptType -eq $efiGptType -and (-not $_.DriveLetter -or $_.DriveLetter -eq [char]0)
}
if ($efiParts)
{
# Find an available drive letter (Z downward to avoid conflicts)
$usedLetters = @()
Get-Volume -ErrorAction SilentlyContinue | Where-Object { $_.DriveLetter } | ForEach-Object { $usedLetters += $_.DriveLetter }
$tempLetter = $null
foreach ($l in @('Z','Y','X','W','V','U','T','S','R','Q')) {
if ($l -notin $usedLetters) { $tempLetter = $l; break }
}
if ($tempLetter)
{
foreach ($ep in $efiParts)
{
$pn = $ep.PartitionNumber
Log-Info "Assigning temp letter ${tempLetter}: to Disk $diskNum Partition $pn (EFI)..." | Tee-Object -FilePath $logFile -Append
$dpLines = @("select disk $diskNum", "select partition $pn", "assign letter=$tempLetter")
$dpLines | diskpart | Out-Null
Start-Sleep -Seconds 2
$bcdPath = "${tempLetter}:\efi\microsoft\boot\bcd"
$isBcdPath = Test-Path $bcdPath
if ($isBcdPath)
{
Log-Info "Found Gen2 BCD store at $bcdPath" | Tee-Object -FilePath $logFile -Append
$tempEfiLetter = $tempLetter
$tempEfiDiskNum = $diskNum
$tempEfiPartNum = $pn
break
}
else
{
Log-Info "No BCD at $bcdPath, removing letter..." | Tee-Object -FilePath $logFile -Append
$dpRemove = @("select disk $diskNum", "select partition $pn", "remove letter=$tempLetter")
$dpRemove | diskpart | Out-Null
}
}
}
else
{
Log-Warning "No available drive letter for EFI partition on Disk $diskNum" | Tee-Object -FilePath $logFile -Append
}
}
}
}
}

# 4. Apply SAC Changes if BCD is found
if ( $isBcdPath -and $isOsPath )
{
# Capture the target ID (usually {default})
$bcdout = bcdedit /store $bcdPath /enum bootmgr /v
$defaultLine = $bcdout | Select-String 'displayorder' | select -First 1

if ($defaultLine -match '\{([^}]+)\}') {
$defaultId = $matches[0]

Log-Output "--- BCD BEFORE SAC ENABLE ---" | Tee-Object -FilePath $logFile -Append
$beforeBcd = bcdedit /store $bcdPath /enum $defaultId
foreach ($line in $beforeBcd) { if ($line.Trim()) { Log-Output $line | Tee-Object -FilePath $logFile -Append } }

Log-Info "Applying SAC and EMS configurations..." | Tee-Object -FilePath $logFile -Append

# Core Logic from Original Script
bcdedit /store $bcdPath /set "{bootmgr}" displaybootmenu yes | Out-Null
bcdedit /store $bcdPath /set "{bootmgr}" timeout 5 | Out-Null
bcdedit /store $bcdPath /set "{bootmgr}" bootems yes | Out-Null
bcdedit /store $bcdPath /ems $defaultId ON | Out-Null
$res = bcdedit /store $bcdPath /emssettings EMSPORT:1 EMSBAUDRATE:115200

Log-Output "Result: $res" | Tee-Object -FilePath $logFile -Append

# --- AFTER CHANGE (Line-by-Line Logging) ---
Log-Output "--- BCD AFTER SAC ENABLE ---" | Tee-Object -FilePath $logFile -Append
$afterBcd = bcdedit /store $bcdPath /enum $defaultId
foreach ($line in $afterBcd) { if ($line.Trim()) { Log-Output $line | Tee-Object -FilePath $logFile -Append } }
# Apply SAC changes if both BCD and OS loader were found
if ( $isBcdPath -and $isOsPath )
{
# Step 2 - Identify the default boot entry GUID
$bcdout = bcdedit /store $bcdPath /enum bootmgr /v
$defaultLine = $bcdout | Select-String 'displayorder' | select -First 1

return $STATUS_SUCCESS
if ($defaultLine -match '\{([^}]+)\}') {
$defaultId = $matches[0]

# Step 3 - Log BCD configuration before changes
Log-Output "--- BCD BEFORE SAC ENABLE ---" | Tee-Object -FilePath $logFile -Append
$beforeBcd = bcdedit /store $bcdPath /enum $defaultId
foreach ($line in $beforeBcd) { if ($line.Trim()) { Log-Output $line | Tee-Object -FilePath $logFile -Append } }

# Steps 4-7 - Enable boot menu, Boot EMS, EMS on OS entry, and EMS serial settings
Log-Info "Applying SAC and EMS configurations..." | Tee-Object -FilePath $logFile -Append
bcdedit /store $bcdPath /set "{bootmgr}" displaybootmenu yes | Out-Null
bcdedit /store $bcdPath /set "{bootmgr}" timeout 5 | Out-Null
bcdedit /store $bcdPath /set "{bootmgr}" bootems yes | Out-Null
bcdedit /store $bcdPath /ems $defaultId ON | Out-Null
$res = bcdedit /store $bcdPath /emssettings EMSPORT:1 EMSBAUDRATE:115200

Log-Output "Result: $res" | Tee-Object -FilePath $logFile -Append

# Step 8 - Log BCD configuration after changes for verification
Log-Output "--- BCD AFTER SAC ENABLE ---" | Tee-Object -FilePath $logFile -Append
$afterBcd = bcdedit /store $bcdPath /enum $defaultId
foreach ($line in $afterBcd) { if ($line.Trim()) { Log-Output $line | Tee-Object -FilePath $logFile -Append } }

$script_final_status = $STATUS_SUCCESS
}
}

# Clean up temporary EFI drive letter if one was assigned
if ($tempEfiLetter)
{
Log-Info "Removing temp letter ${tempEfiLetter}: from Disk $tempEfiDiskNum Partition $tempEfiPartNum" | Tee-Object -FilePath $logFile -Append
$dpClean = @("select disk $tempEfiDiskNum", "select partition $tempEfiPartNum", "remove letter=$tempEfiLetter")
$dpClean | diskpart | Out-Null
}
}

if ($script_final_status -ne $STATUS_SUCCESS) {
Log-Error "FAILED: Script could not find a valid OS disk to enable SAC." | Tee-Object -FilePath $logFile -Append
}
}
catch {
Log-Error "An error occurred: $($_.Exception.Message)" | Tee-Object -FilePath $logFile -Append
$script_final_status = $STATUS_ERROR
}
finally {
Log-Info "Script ended at $(Get-Date)" | Tee-Object -FilePath $logFile -Append
}

Log-Error "FAILED: Script could not find a valid OS disk to enable SAC." | Tee-Object -FilePath $logFile -Append
return $STATUS_ERROR
return $script_final_status