Inofficial Library for basic communication to bluetti powerstations. Core functions based on https://github.com/warhammerkid/bluetti_mqtt
The current Roadmap for this project and repositories using this library can be found here
This library is provided without any warranty or support by Bluetti. I do not take responsibility for any problems it may cause in all cases. Use it at your own risk.
- Home Assistant Integration
- MQTT Server (planned)
- UPS Server (NUT compatible) (planned)
Validated
| Device Name | total_battery_percent | dc_input_power | ac_input_power | dc_output_power | ac_output_power |
|---|---|---|---|---|---|
| AC70 | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC180 | ✅ | ✅ | ✅ | ✅ | ✅ |
| EB3A | ✅ | ✅ | ✅ | ✅ | ✅ |
| EP600 | ✅ | PV | Grid | ❌ | AC Phases |
| Handsfree 1 | ✅ | ✅ | ✅ | ✅ | ✅ |
Added and mostly validated by contributors (some are moved here from the HA Integration https://github.com/Patrick762/hassio-bluetti-bt):
| Device Name | Contributor | total_battery_percent | dc_input_power | ac_input_power | dc_output_power | ac_output_power |
|---|---|---|---|---|---|---|
| AC2A | @ruanmed | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC50B | @goetzc | ✅ | ❌ | ✅ | ✅ | ✅ |
| AC60 | @mzpwr | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC60P | @mzpwr | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC70P | @matthewpucc | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC180P | @Patrick762 | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC200L | bluetti-mqtt | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC200M | bluetti-mqtt | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC200PL | @0x4E4448 | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC300 | bluetti-mqtt | ✅ | ✅ | ✅ | ✅ | ✅ |
| AC500 | bluetti-mqtt | ✅ | ✅ | ✅ | ✅ | ✅ |
| AP300 | @seaburger | ✅ | ✅ | ✅ | ❌ | ✅ |
| EL30V2 | @dgudim | ✅ | ✅ | ✅ | ✅ | ✅ |
| EL100V2 | @seaburger | ✅ | ✅ | ✅ | ✅ | ✅ |
| EP500 | bluetti-mqtt | ✅ | ✅ | ✅ | ✅ | ✅ |
| EP500P | bluetti-mqtt | ✅ | ✅ | ✅ | ✅ | ✅ |
| EP760 | @Apfuntimes | ✅ | PV | Grid | ❌ | AC Phases |
| EP800 | @jhagenk | ✅ | ❌ | ❌ | ❌ | ❌ |
Currently only "switches" are supported
Validated
| Device Name | ctrl_ac | ctrl_dc |
|---|---|---|
| EB3A | ✅ | ✅ |
Data for battery packs will no longer be available in this library
pip install bluetti-bt-libCommands included in this library should only be used for testing.
usage: bluetti-scan [-h]
Detect bluetti devices by bluetooth name
options:
-h, --help show this help message and exitExample output: ['EB3A', '00:00:00:00:00:00']
usage: bluetti-detect [-h] mac
Detect bluetti devices
positional arguments:
mac Mac-address of the powerstation
options:
-h, --help show this help message and exitExample:
bluetti-detect 00:00:00:00:00:00Example output: Device type is 'EB3A' with iot version 1 and serial 0000000000000. Full name: EB3A0000000000000
usage: bluetti-read [-h] [-m MAC] [-t TYPE] [-e ENCRYPTION]
Detect bluetti devices
options:
-h, --help show this help message and exit
-m MAC, --mac MAC Mac-address of the powerstation
-t TYPE, --type TYPE Type of the powerstation (AC70 f.ex.)
-e ENCRYPTION, --encryption ENCRYPTION
Add this if encryption is neededExample:
bluetti-read -m 00:00:00:00:00:00 -t EB3AExample output:
FieldName.DEVICE_TYPE: EB3A
FieldName.DEVICE_SN: 0000000000000
FieldName.BATTERY_SOC: 92%
FieldName.DC_INPUT_POWER: 0W
FieldName.AC_INPUT_POWER: 0W
FieldName.AC_OUTPUT_POWER: 0W
FieldName.DC_OUTPUT_POWER: 0W
FieldName.CTRL_AC: False
FieldName.CTRL_DC: True
FieldName.CTRL_LED_MODE: LedMode.OFF
FieldName.CTRL_POWER_OFF: False
FieldName.CTRL_ECO: False
FieldName.CTRL_ECO_TIME_MODE: EcoMode.HOURS1
FieldName.CTRL_CHARGING_MODE: ChargingMode.STANDARD
FieldName.CTRL_POWER_LIFTING: FalseINFO: Devices with encryption are currently not supported!
usage: bluetti-write [-h] [-m MAC] [-t TYPE] [--on ON] [--off OFF] [-v VALUE] [-e ENCRYPTION] field
Write to bluetti device
positional arguments:
field Field name (ctrl_dc f.ex.)
options:
-h, --help show this help message and exit
-m MAC, --mac MAC Mac-address of the powerstation
-t TYPE, --type TYPE Type of the powerstation (AC70 f.ex.)
--on ON Value to write
--off OFF Value to write
-v VALUE, --value VALUE
Value to write (integer, see enum for value)
-e ENCRYPTION, --encryption ENCRYPTION
Add this if encryption is neededExample:
bluetti-write -m 00:00:00:00:00:00 -t EB3A --on on ctrl_acTo add new fields, you can use the bluetti-detect command to first find out which version of iot protocol is used and if it uses encryption.
After you got this information, you can use the bluetti-readall command to read every registry and save the data to a json file. You should also note all values you see in the app to later compare the data.
Here's how to use the bluetti-readall command:
usage: bluetti-readall [-h] [-m MAC] [-v VERSION] [-e ENCRYPTION]
Detect bluetti devices
options:
-h, --help show this help message and exit
-m MAC, --mac MAC Mac-address of the powerstation
-v VERSION, --version VERSION
IoT protocol version
-e ENCRYPTION, --encryption ENCRYPTION
Add this if encryption is neededWith the separate tool at bluetti-bt-raw-reader you can view those values in a more understandable way.
You can also share the output with me using this form
To test added fields with the created json file, use bluetti-parse:
usage: bluetti-parse [-h] file
Parse readall output files
positional arguments:
file JSON file of the powerstation readall output
options: