Skip to content

set temperature instance to 0 instead of 107 - #76

Open
sivu wants to merge 1 commit into
SignalK:masterfrom
sivu:temperature_instance
Open

set temperature instance to 0 instead of 107#76
sivu wants to merge 1 commit into
SignalK:masterfrom
sivu:temperature_instance

Conversation

@sivu

@sivu sivu commented May 30, 2023

Copy link
Copy Markdown

I had an issue that the temperature values sent by signalk were not displayed on nmea displays (Canview, maretron dsm410, simrad autopilot). setting the instance id to 0 solved the issue. Ideally the instance id should be a configuration option in plugin config.

…isible

to canview, maretron dsm410, and simrad autopilot device view
@tkurki

tkurki commented May 9, 2024

Copy link
Copy Markdown
Member

Making the insfance id configurable should be fairly easy. Could you look into it?

@tkurki

tkurki commented Apr 28, 2025

Copy link
Copy Markdown
Member

@sbender9 is there something magical about 107?

@sbender9

Copy link
Copy Markdown
Member

@sbender9 is there something magical about 107?

No. Random.

@sbender9

Copy link
Copy Markdown
Member

Of course, changing it now could mess with people's existing installs.

@sivu

sivu commented Apr 28, 2025

Copy link
Copy Markdown
Author

since instances are usually in the range of <10, some devices do not want to understand instance id >100

@sbender9

Copy link
Copy Markdown
Member

I think we just need to make it configurable and default to 107 for existing installs.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment