Sine Wave Generation using Xilinx DDS Compiler

This project demonstrates generating sine waves on FPGA using the Xilinx DDS Compiler IP. The goal is to document the configuration choices, frequency resolution, and supporting RTL logic used in the design.


Source Files

File Description
src/one_pulse_after_n.vhd One-shot pulse generator — fires PULSE_LEN cycles starting N clocks after reset

Frequency Resolution

The DDS output frequency is controlled by the Frequency Tuning Word (FTW).

$$ f_\text{out} = \frac{FTW}{2^N} \cdot f_\text{clk} $$

With:

  • System clock: $$f_\text{clk} = 100\ \text{MHz}$$
  • Phase width: $$N = 32\ \text{bits}$$

We obtain:

  • $$2^{32} = 4,294,967,296$$
  • FTW per Hz: $$ \frac{2^{32}}{f_\text{clk}} = \frac{4,294,967,296}{100,000,000} \approx 42.95 $$
  • Frequency resolution (Hz per FTW): $$ \frac{f_\text{clk}}{2^{32}} \approx 0.0233\ \text{Hz} $$

This means every increment of the FTW corresponds to ~23 mHz at a 100 MHz clock.


DDS Compiler Configuration

Key configuration parameters:

  • Phase Width: 32 bits
  • Output Width: 16 bits
  • Phase Increment: Programmable (allows dynamic frequency updates)
  • Output Selection: Sine only
  • Phase Output: Disabled

DDS Configuration DDS Compiler configuration menu.

DDS Implementation Options DDS Compiler implementation options.


Block Design

The DDS Compiler is instantiated alongside a simple RTL module that generates a one-shot pulse. This pulse updates the FTW exactly once after reset, ensuring clean frequency initialization.

Block Design Vivado block design integrating DDS Compiler and control logic.


One-Pulse Generator RTL

The one_pulse_after_n RTL module generates a single output pulse after N clock cycles. This pulse can optionally be stretched to PULSE_LEN cycles. It is used here to trigger the FTW update to the DDS Compiler.

library IEEE;
use IEEE.STD_LOGIC_1164.ALL;

entity one_pulse_after_n is
  generic(
    N         : integer := 10;  -- wait N clocks
    PULSE_LEN : integer := 1    -- pulse length in clocks
  );
  port(
    clk   : in  std_logic; 
    rst   : in  std_logic;  -- synchronous reset, active high
    pulse : out std_logic
  );
end entity;

architecture rtl of one_pulse_after_n is
  signal cnt  : integer range 0 to N+PULSE_LEN := 0;
  signal done : std_logic := '0';
begin
  process(clk)
  begin
    if rising_edge(clk) then
      if rst = '1' then
        cnt  <= 0;
        done <= '0';
      else
        if done = '0' then
          cnt <= cnt + 1;
          if cnt = N+PULSE_LEN then
            done <= '1';
          end if;
        end if;
      end if;
    end if;
  end process;

  pulse <= '1' when (done='0') and (cnt > N) and (cnt <= N+PULSE_LEN) else '0';
end architecture;

Simulation Results

A simulation testbench confirms correct sine wave generation. With an FTW value of 42,949,672, the output frequency matches the expected calculation.

Simulation Output Simulation waveform: sine output with valid FTW update.


How to Calculate FTW for a Target Frequency

To generate a desired output frequency $$f_\text{out}$$, compute the FTW as:

$$ FTW = \frac{f_\text{out}}{f_\text{clk}} \cdot 2^N $$

Example 1: 1 kHz output

$$ FTW = \frac{1000}{100 \times 10^6} \cdot 2^{32} \approx 42{,}950 $$

Example 2: 10 kHz output

$$ FTW = \frac{10{,}000}{100 \times 10^6} \cdot 2^{32} \approx 429{,}497 $$

Example 3: 1 MHz output

$$ FTW = \frac{1{,}000{,}000}{100 \times 10^6} \cdot 2^{32} \approx 42{,}949{,}672 $$


Quick Reference Table (100 MHz clock, 32-bit phase accumulator)

Output Frequency FTW Value
1 Hz 42.95
10 Hz 429.5
100 Hz 4,295
1 kHz 42,950
10 kHz 429,497
100 kHz 4,294,967
1 MHz 42,949,672
10 MHz 429,496,729
25 MHz 1,073,741,824
50 MHz (Nyquist) 2,147,483,648

Note: FTW values are rounded to the nearest integer.


Bonus

We can also get both sine and cosine signals at the same time by choosing Sine and Cosine at the output selection and seperate them like the following way. bd2 tb2


Summary

  • A 32-bit DDS accumulator running at 100 MHz yields a frequency resolution of ~0.023 Hz.
  • The FTW controls output frequency directly, with ~42.95 FTW units per Hz.
  • A simple pulse generator ensures a single clean configuration update after reset.
  • The design is fully parameterized and can be extended for programmable sweeps or dynamic frequency control.
  • The quick reference table makes it easy to choose FTW values for common target frequencies.